Function OC1: Open-collector output 1 (terminal 21)
TAB3
Range:
−
11..0..
+
11
Default:
−
2
Function OC2: Open-collector output 2 (terminal 22)
TAB3
The functions OC1 and OC2 define the condition which will cause the open-collector out-
puts to operate. It may be programmed to one of 11 conditions.
Sign + : NOT ACTIVE (HIGH) at condition.
Sign - : ACTIVE (LOW) at condition.
code
0: Motor speed greather than FX1 (TAB1, function U).
1: Motor speed greather than FX2 (TAB1, function u).
2: Motor has reached the end of the ramp. Indication at 0Hz included.
3: Motor speed = 0 Hz.
4: Motor speed = 0 Hz. Message at the end of the torque holding time
(see TAB1, function 9).
5: Output current threshold exceeded (TAB1, SUB IMOT, function S).
6: Output current threshold exceeded; message at the end of the programmed
delay time (TAB1, SUB IMOT, function DY).
7:
+
: Output activ when motor rotates in counter-clockwise direction (CCW).
- : Output activ when motor rotates in clockwise direction (CW).
8: The dynamic braking power is near the programmed limit
(TAB2, function BrLim).
9: Motor has reached the end of the ramp. Indication at 0Hz excluded.
10:
The inverter (heat sink) temperature reaches the limit value.
(Only with Softw. D2A-STD).
11:
The motor temperature reaches the limit value.
(Only with ACM D2 30.0 - 37.0 kW and Softw. D2A-STD).
Range:
−
11..0..
+
11
Default:
−
0
OC1
−
2
OC2
−
0
BERGES electronic
48 Operating manual ACM D2/S2 09.07.2001
Содержание ACM S2
Страница 1: ...Operating manual ACM D2 S2 ...
Страница 2: ......
Страница 28: ...15 Programming ACM D2 S2 15 1 Program structure BERGES electronic 26 Operating manual ACM D2 S2 09 07 2001 ...
Страница 29: ...BERGES electronic 09 07 2001 Operating manual ACM D2 S2 27 ...
Страница 60: ...20 Notes BERGES electronic 58 Operating manual ACM D2 S2 09 07 2001 ...
Страница 61: ...BERGES electronic ...
Страница 62: ...BERGES electronic ...
Страница 63: ......