Function PASS: PASSWORD
TAB2
If a password has been assigned (PASSWORD <> "000"), to enter the functions
SECUR and SET PASS, the access code must be entered in this function.
Function SECUR: Security code
TAB2
Setting of the requested security level:
0: SECURITY off.
1: SECURITY Level 1
Parameters can be modified but not saved.
Any attempt to save will be interrupted and the message "SECUR.1" will be
displayed.
2: SECURITY Level 2
Parameters cannot be modified or saved.
Any attempt to modify or save will be interrupted and the message
"SECUR. 2" will be displayed.
Range: 0...2
Default: 0
Function SET PASS: SET PASSWORD
TAB2
This function is used to set a password. If a password has been assigned (PASS -
WORD <> "000"), to enter the functions SECUR and SET PASS, the access code
must be entered in function PASSWORD.
Range: 0...999
Default: 0
Save parameter
TAB2
By pressing both INC and DEC simultaneously the parameter values are stored in the
internal non-volatile inverter memory. At the end of the Save-function the program re-
turns to TAB2, function CLIP.
15.4. Program level TAB3
Program level TAB3
TAB3
The program level functions in TAB3 allows to configure the outputs, to access the dia-
gnostic utilities and to program extended parameters.
PASS 000
SECUR. 0
SET 000
SAVE ??
TAB 3
BERGES electronic
09.07.2001 Operating manual ACM D2/S2 43
Содержание ACM S2
Страница 1: ...Operating manual ACM D2 S2 ...
Страница 2: ......
Страница 28: ...15 Programming ACM D2 S2 15 1 Program structure BERGES electronic 26 Operating manual ACM D2 S2 09 07 2001 ...
Страница 29: ...BERGES electronic 09 07 2001 Operating manual ACM D2 S2 27 ...
Страница 60: ...20 Notes BERGES electronic 58 Operating manual ACM D2 S2 09 07 2001 ...
Страница 61: ...BERGES electronic ...
Страница 62: ...BERGES electronic ...
Страница 63: ......