Operation
60
Operating Instructions 1280-7/1281-7 - 00.0 - 01/2023
Fig. 53: Operating the mouse station (2)
4. While the sewing process is in progress, the mouse station (13) is
guided along the guide rail (12) by the guide roller (15) and the guiding
pins (16).
5. Once it reaches the end stop-front (11), the opening of the mouse
clamp (5) is triggered automatically.
The lever (1) is moved in arrow direction (17) by the end stop-front (11).
The mouse clamp (4) opens towards the top in arrow direction (14).
The sewing piece (4) detaches from the needle (9) and thus from
the mouse station (13).
Fig. 54: Operating the mouse station (3)
6. The mouse station (13) is pulled back by the retrieval device (
)
until it abuts on the end stop-rear (18).
(11) - End stop - front
(12) - Guide rail
(13) - Mouse station
(14) - Arrow direction
(15) - Guide roller
(16) - Guide pins
(17) - Arrow direction
⑭
⑪
⑫
⑬
⑯
⑰
⑮
(18) - End stop - rear