Global parameters
The global parameters allow the user to set/adjust parameters that apply
to all programs. The following tables provides an overview of the structure
of the
1.3
Global Parameters
(they are valid for all programs).
Selection
Setting 1
Setting 2
1.3.1
Light barrier
Select to view
photo cell menu
1.3.1.2
Delay to
lower the sewing foot
The delay for lowering the
presser foot after light barrier
detection facilitates material feed
under the presser foot.
Default: 0.2 Sec.
Value range:
0.00-1.00 Sec.
1.3.1.3
Automatic sewing start
delay
Delay for automatic sewing start,
for secure positioning of the sew-
ing material under the presser
foot.
Default: 0.1 Sec.
Value range:
0.00-5.00 Sec.
1.3.1.4
Delay of sewing foot
lift after seam end
The delay of the sewing foot lift
at the seam end ensures that the
thread chain cutting works safely.
Default: 0.2 Sec.
Value range:
0.00-1.00 Sec.
1.3.2
Thread ten-
sion release
The thread tension
release is used to
support the safe
chain cutting when
serging 3-thread
seams.
1.3.2.1
Thread tension release
at the seam beginning
Default: Off
Value range: ON/OFF