Maintenance
Operating Instructions 1280-7/1281-7 - 00.0 - 01/2023
179
Fig. 138: Draining the water condensation
To drain water condensation:
1. Disconnect the machine from the compressed air supply.
2. Place the collection tray under the drain screw (3).
3. Loosen the drain screw (3) completely.
4. Allow water to drain into the collection tray.
5. Tighten the drain screw (3).
6. Connect the machine to the compressed air supply.
6.3.3
Cleaning the filter element
(1) - Filter element
(2) - Water separator
(3) - Drain screw
①
②
③
NOTICE
Damage to the paintwork from solvent-based cleaners!
Solvent-based cleaners damage the filter.
Use only solvent-free substances for washing out the filter tray.