14/4798.495.002
Prior to installation | 43
Dachs Pro 20 ST
Note:
At temperatures below 10 °C, the temperature-related viscosity of the
engine oil may lead to starting problems.
i
●
Heating room according to DVGW TRGI.
●
Specific installation room.
●
Room approved according to the ordinance for use of heating appliances or national regulations.
The room must fulfil the following specific criteria:
●
Level foundation with a maximum incline of 1 % according to DIN EN 12828.
●
Room only for fuel burning installations, heating pumps, combined heat and power stations and stationary
combustion engines.
●
No openings to other rooms except doors.
●
Sufficient lighting.
●
Room ventilation.
●
Frost-protected.
●
Socket recommended.
●
Appropriately labelled emergency switch outside of the room.
The Dachs Pro 20 ST must not be operated in rooms where considerable air pollution by hydrogen halide is to be expected.
For example:
●
Hairdressers
●
Printing houses
●
Chemical cleaners
●
Laboratories, etc.
●
as well as in rooms with high dust content or a high level of humidity (e.g. laundry rooms).
For storage:
Temperature: 5 - 60 °C
Humidity: up to 90 %
During operation:
Temperature: 5 - 35 °C
Humidity: up to 70 %
5.3.1 Installation requirements
5.3.2 Ambient conditions:
Содержание Senertec Dachs Pro 20 ST