
en_BA_PosCon_OXE7.docx
8/75
Baumer Electric AG
04.01.2021 15:33/adr V1.3 ANW_81125407
Frauenfeld, Switzerland
WIDTH: Width measurement
To perform width measurement, select FUNCTION
"WIDTH" in the menu. In WIDTH the desired output is
selected in the MEAS TYPE menu.
OBJECT WIDTH
= Distance between the first rising
flank from the left and the first
rising flank from the right.
OBJECT CENTER
= Center between the first
rising flank from the left and the
first rising flank from the right in
relation to the measuring axis of
the sensor.
OBJECT WIDTH
OBJECT CENTER
OBJECT HEIGHT
Minimum height of the object to be measured.
OBJECT
Selection of light or dark objects to optimize the
measurement results.
PRECISION
For more reliable measurement results, the output values
can be filtered with High and Very High.
FLEX MOUNT
If the sensor is mounted at an angle, FLEX MOUNT must
be activated and the reference surface must be taught in.
1. Activate FLEX MOUNT
2. Align and confirm sensor or reference surface
3. When all conditions are met (see table on right),
confirm by pressing Set for 2 seconds
4. Enter thickness of the auxiliary plate (if present)
Distance between sensor
and reference surface
Installation angle too
large
Reference surface too
uneven
Reference surface too
small (<50 mm)
3b
Min. object height
Object
Reference
surface
Содержание PosCon OXE7
Страница 1: ...Operating instructions PosCon OXE7 Edge measurement in a new dimension...
Страница 27: ...en_BA_PosCon_OXE7 docx 27 75 Baumer Electric AG 04 01 2021 15 33 adr V1 3 ANW_81125407 Frauenfeld Switzerland...
Страница 52: ...6 2 Dimensions Optical axis...
Страница 75: ...en_BA_PosCon_OXE7 docx 75 75 Baumer Electric AG 04 01 2021 15 33 adr V1 3 ANW_81125407 Frauenfeld Switzerland...