5.1.4
Further key functions
Action
Reaction
Slide over all keys from left to right
Unlock locked touch panel
Only if touch panel is locked
Slide over all keys from right to left
Jump directly to run mode
Can be used from any menu
5.1.5
LEDs on the sensor
LED
Lights up
Flashes
Yellow
out1 activated
Adjustable switching output1 activated
-
Red
out2 activated
Alarm or error. Object to be measured
outside measuring field or invalid received
signal (e.g. soiling)
Insufficient excess gain
Object just under the measuring range limit or
insufficient received signal (e.g. soiling)
Green
Supply voltage
Sensor ready for operation
Short circuit
Check connection