en_BA_PosCon_OXE7.docx
13/75
Baumer Electric AG
04.01.2021 15:33/adr V1.3 ANW_81125407
Frauenfeld, Switzerland
4
Installation
4.1
Mounting
The sensor has four mounting holes for flexible alignment and mounting. The use of 2 M4x35 screws is
recommended for mounting. The tightening torque is max. 1.2 Nm.
4.2
Sensor reference levels
To ensure easy alignment of the sensor during installation, the surfaces defined here are available:
The laser beam of the sensor runs parallel ( // ) to level R3 and is at a right angle to levels R1 and R2. Levels
R1, R2, and R3 serve as a reference for sensor alignment during installation. "Left" and "Right" designations
are also important.
19
m
m
Level R3
Laser
beam
Level R1
Level R2
13 mm
Tightening torque
max. = 1.2 Nm
ATTENTION!
Connection, installation and commissioning may only be performed by qualified
personnel. Protect optical surfaces from moisture and dirt.
Left
Right
Содержание PosCon OXE7
Страница 1: ...Operating instructions PosCon OXE7 Edge measurement in a new dimension...
Страница 27: ...en_BA_PosCon_OXE7 docx 27 75 Baumer Electric AG 04 01 2021 15 33 adr V1 3 ANW_81125407 Frauenfeld Switzerland...
Страница 52: ...6 2 Dimensions Optical axis...