en_BA_PosCon_OXE7.docx
48/75
Baumer Electric AG
04.01.2021 15:33/adr V1.3 ANW_81125407
Frauenfeld, Switzerland
1
FLEX MOUNT activated, inclined 30° and max. measuring field
High
Very high
7 16
15 128
7 16
15 128
7 16
15 128
7 16
15 128
Power on indication
Green LED
Green LED
Green LED
Green LED
Output indicator
Yellow LED / red LED
Yellow LED / red LED
Yellow LED / red LED
Yellow LED / red LED
FLEX MOUNT Distance between
sensor and reference surface
180…250 mm
180…250 mm
115
…150 mm
115
…150 mm
Max. reference surface
unevenness
1 mm
1 mm
0.5 mm
0.5 mm
Min. reference surface length
50 mm
50 mm
24 mm
24 mm
Max. cable length
5 m up to the neutral point
5 m up to the neutral point
5 m up to the neutral point
5 m up to the neutral point
Setting
Touch display, RS485
Touch display, RS485
Touch display, RS485
Touch display, RS485
Heating period
15 min
15 min
15 min
15 min
Temperature drift
< 0.05% measuring value/K
< 0.05% measuring value/K
< 0.03% measuring value/K
< 0.03% measuring value/K
Analog output scaling:
Voltage output
Current output
0.05 V/mm
0.1 mA/mm
0.05 V/mm
0.1 mA/mm
0.1 V/mm
0.16 mA/mm
0.1 V/mm
0.16 mA/mm
Electrical data
PosCon OXE7
11111452
OXE7.E25T-11111452
PosCon OXE7
11174280
OXE7.E25T-11174280
PosCon OXE7
11148276
OXE7.E25T-11148276
PosCon OXE7
11177353
OXE7.E25T-11177353
Voltage supply range +Vs
15 ... 28 VDC
15 ... 28 VDC
15 ... 28 VDC
15 ... 28 VDC
Max. supply current (without load)
150 mA
150 mA
150 mA
150 mA
Output circuit
Analog and RS485
Analog and RS485
Analog and RS485
Analog and RS485
Output signal
4 ... 20 mA / 0 ... 10 VDC
1
4 ... 20 mA / 0 ... 10 VDC
4 ... 20 mA / 0 ... 10 VDC
4 ... 20 mA / 0 ... 10 VDC
Switching output
Push-pull
Push-pull
Push-pull
Push-pull
Switching function
Out 1 / alarm
Out 1 / alarm
Out 1 / alarm
Out 1 / alarm
Output current
< 100 mA
< 100 mA
< 100 mA
< 100 mA
Baud rate
115200, adjustable
115200, adjustable
115200, adjustable
115200, adjustable
Reverse polarity protection
Yes, Vs to GND
Yes, Vs to GND
Yes, Vs to GND
Yes, Vs to GND
Short circuit protection
Yes
Yes
Yes
Yes
Содержание PosCon OXE7
Страница 1: ...Operating instructions PosCon OXE7 Edge measurement in a new dimension...
Страница 27: ...en_BA_PosCon_OXE7 docx 27 75 Baumer Electric AG 04 01 2021 15 33 adr V1 3 ANW_81125407 Frauenfeld Switzerland...
Страница 52: ...6 2 Dimensions Optical axis...
Страница 75: ...en_BA_PosCon_OXE7 docx 75 75 Baumer Electric AG 04 01 2021 15 33 adr V1 3 ANW_81125407 Frauenfeld Switzerland...