2.2
Installation
Standard installation
In standard installation, the sensor is mounted at a
right angle to the reference surface or the object. The
sensor is not taught into the reference surface so
configuration is very easy and straightforward.
This installation method is recommended even if the
reference surface cannot be taught in for some
reason or another.
Angled installation
In angled installation, the sensor can be mounted
at an angle of up to +/- 30° in relation to the
reference surface. This installation method is used
when space conditions do not allow any other
installation option or the mounting angle is not
known.
Align the sensor as accurately as possible at a right
angle to the reference surface (background) or to the
object (if there is no reference surface in the
measuring field). The object must be within the
measuring field, i.e. the distance from the sensor
must be between the start of the measuring range
Sdc and the end of the measuring range Sde. The
reference surface can lie outside of the
measurement field or can be non-existent, this
situation is reffered to as ege-to-infinity.
The sensor may be mounted at an angle inclined
maximally 30° to the left or to the right of the
reference surface (background) or to the object (if
there is no reference surface in the measuring
field).
Reference surface (background) and object must
be within the measuring field.
2
NOTE
The "Edge L rise or Edge R rise" mode can be used as an aid to find the zero point.
Now an object is slowly pushed toward the presumed zero point. The zero point is
reached by the rising edge of the object when the value 0 mm is shown on the sensor
display and the yellow LED switches.
0 mm
Reference point
Measuring field
width right
Measuring field
width left
Right
Left
Blind region
Start of measuring
range Sdc
MEASURING
FIELD
0 mm
Reference
point
Right
Left
0 mm
MEASURING
FIELD
+/-30°
Reference surface
Measuring field
width left
Measuring field
width right
Blind region
End of measuring
range Sde
Содержание PosCon OXE7
Страница 1: ...Operating instructions PosCon OXE7 Edge measurement in a new dimension...
Страница 27: ...en_BA_PosCon_OXE7 docx 27 75 Baumer Electric AG 04 01 2021 15 33 adr V1 3 ANW_81125407 Frauenfeld Switzerland...
Страница 52: ...6 2 Dimensions Optical axis...
Страница 75: ...en_BA_PosCon_OXE7 docx 75 75 Baumer Electric AG 04 01 2021 15 33 adr V1 3 ANW_81125407 Frauenfeld Switzerland...