5.8.1
No
"No" deactivates FLEX MOUNT, the sensor can be remounted in standard installation.
If FLEX MOUNT is not activated, angle 0° and distance "End of measuring range Sde“ are set.
The angle symbol
disappears from the display.
5.8.2
Yes
FLEX MOUNT is activated in this menu item when the sensor is to be mounted at an angle.
Next, "Place the reference (REF)" is output by the sensor and then the sensor must be aligned to the
reference surface (or the auxiliary plate if there is no reference surface).
Auxiliary plate
To compensate for unevenness and increase accuracy, a flat temporary auxiliary plate can be used for this
process. It is placed on the reference surface during teaching-in and removed after the process.
This plate should be as even as possible and must cover the "minimum reference surface length". The plate
must be positioned parallel to the reference surface below it. The thickness of this plate is not important as
long as it is within the measuring field of the sensor.
Auxiliary plate during the
teaching-in process
Reference surface
uneven
M
K
Left
Right
Minimum length of reference
surface or auxiliary plate
Distance between
sensor and reference
surface
THICKNESS REF
NOTE
The following menu items TEACH REF and THICKNESS REF must be completed
so that FLEX MOUNT can be activated.
Содержание PosCon OXE7
Страница 1: ...Operating instructions PosCon OXE7 Edge measurement in a new dimension...
Страница 27: ...en_BA_PosCon_OXE7 docx 27 75 Baumer Electric AG 04 01 2021 15 33 adr V1 3 ANW_81125407 Frauenfeld Switzerland...
Страница 52: ...6 2 Dimensions Optical axis...
Страница 75: ...en_BA_PosCon_OXE7 docx 75 75 Baumer Electric AG 04 01 2021 15 33 adr V1 3 ANW_81125407 Frauenfeld Switzerland...