en_BA_PosCon_OXE7.docx
18/75
Baumer Electric AG
04.01.2021 15:33/adr V1.3 ANW_81125407
Frauenfeld, Switzerland
4.5.2
Blind region
The region up to the start of measuring range Sdc is called the blind region, i.e. the sensor cannot detect any
objects there.
Nevertheless, placing an object there should be avoided since the resulting shadowing of objects could
produce incorrect measuring values.
4.6
Angled installation
Compared to standard installation, the sensor can be mounted at an arbitrary inclination angle up to ±30°.
This is particularly useful when space conditions do not allow any other installation option. See Section FLEX
MOUNT.
The object must be within the measuring field.
0 … -30°
+30 … 0°
Reference surface
K
M
Me
as
uri
ng
ran
ge
Measuring
field
Blind
r
egio
n
Object
Start of measuring range
Sdc
End of measuring range
Sde