8.2
The dependency of the measuring frequency
Since the measuring frequency is dependent on various factors, the measuring frequency is specified in the
data sheet as a range (for example 125 ... 500 Hz).
The following factors have an influence on the measuring frequency:
-
Measuring field width
-
Measuring field height
-
OBJECT setting: Bright or dark
The measuring field height influences the measuring frequency more than the limitation of the measuring field
width.
8.2.1
Increasing the measuring frequency
To increase the measuring frequency, the following settings can be made:
Limitation of the measuring field (width)
Limitation of the measuring field with LIMIT LEFT and LIMIT RIGHT as small as possible.
Limitation of the measuring field (height)
Limitation of the measuring field with AUTO H and OFFSET.
LIMIT LEFT
LIMIT RIGHT
OFFSET
AUTO H