Calculating the analog output signal
The measuring values in mm can be converted into the analog output signal with the following formulas.
6.5.2.1
Sensors with measuring range (Distance) 100…150 mm
Fixed scaling:
-
10 mm/V
-
6.25 mm/mA
Function edge or center
𝐎𝐮𝐭𝐩𝐮𝐭 𝐬𝐢𝐠𝐧𝐚𝐥 𝐢𝐧 𝐦𝐀 = 𝟏𝟐𝐦𝐀 + 𝑚𝑒𝑎𝑠𝑢𝑟𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒 𝐢𝐧 𝐦𝐦 ∗ 𝟎. 𝟏𝟔𝐦𝐀/𝐦𝐦
𝐎𝐮𝐭𝐩𝐮𝐭 𝐬𝐢𝐠𝐧𝐚𝐥 𝐢𝐧 𝐕 = 𝟓𝐕 + 𝑚𝑒𝑎𝑠𝑢𝑟𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒 𝐢𝐧 𝐦𝐦 ∗ 𝟎. 𝟏𝐕/𝐦𝐦
Function width or gap width
𝑶𝒖𝒕𝒑𝒖𝒕 𝒔𝒊𝒈𝒏𝒂𝒍 𝒊𝒏 𝒎𝑨 = 4𝑚𝐴 + 𝑚𝑒𝑎𝑠𝑢𝑟𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒 𝑖𝑛 𝑚𝑚 ∗ 0.16𝑚𝐴/𝑚𝑚
𝑶𝒖𝒕𝒑𝒖𝒕 𝒔𝒊𝒈𝒏𝒂𝒍 𝒊𝒏 𝑽 = 𝑚𝑒𝑎𝑠𝑢𝑟𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒 𝑖𝑛 𝑚𝑚 ∗ 0.1𝑉/𝑚𝑚
6.5.2.2
Sensors with measuring range (Distance) 150…250 mm
Fixed scaling:
-
20 mm/V
-
10 mm/mA
Function edge or center
𝐎𝐮𝐭𝐩𝐮𝐭 𝐬𝐢𝐠𝐧𝐚𝐥 𝐢𝐧 𝐦𝐀 = 12 𝑚𝐴 + 𝑚𝑒𝑎𝑠𝑢𝑟𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒 𝑖𝑛 𝑚𝑚 ∗ 0.1 𝑚𝐴/𝑚𝑚
𝐎𝐮𝐭𝐩𝐮𝐭 𝐬𝐢𝐠𝐧𝐚𝐥 𝐢𝐧 𝐕 = 5 𝑉 + 𝑚𝑒𝑎𝑠𝑢𝑟𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒 𝑖𝑛 𝑚𝑚 ∗ 0.05 𝑉/𝑚𝑚
Function width or gap width
𝐎𝐮𝐭𝐩𝐮𝐭 𝐬𝐢𝐠𝐧𝐚𝐥 𝐢𝐧 𝐦𝐀 = 4 𝑚𝐴 + 𝑚𝑒𝑎𝑠𝑢𝑟𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒 𝑖𝑛 𝑚𝑚 ∗ 0.1 𝑚𝐴/𝑚𝑚