CONTENTS
General Information .........................................50
Free Cooling Unit System ................................ 50
Wall-Mount Air Conditioner Units ..................... 50
Controller ...................................................... 50
General ......................................................... 50
Shipping Damage ........................................... 50
Additional Publications ................................... 51
List of Necessary Materials/Tools ..................52
Site Preparation .................................................53
Model Identification ........................................ 53
New Shelter Installation vs. Retrofit Installation 53
Minimum Clearance ........................................ 54
Clearance to Combustibles .............................. 54
Wall-Mount Unit Mounting ..............................56
Mounting the Units ......................................... 56
Supply Air Grill Installation ............................. 56
Wall-Mount Unit Wiring ...................................62
Main Power Wiring .......................................... 62
Unit Control Voltage Wiring .............................. 64
Preliminary Start Up .........................................66
Running in Stand Alone (Orphan) Mode ............ 66
LC6000 Controller Installation ........................67
LC6000 Controller .......................................... 68
Mounting the LC Controller ....................... 68
Installing Remote Indoor
Temperature/Humidity
Sensor(s) ................ 69
Smoke, Hydrogen and Generator Alarms ..... 71
Communication
Wiring .............................. 72
LC6000 Supply Wiring ............................. 77
System Set Up ....................................................80
TEC-EYE
TM
Hand-Held Diagnostic Tool .............. 80
Tec-Eye Status Screen .............................. 80
Setting Up Wall-Mount Units for Operation ....... 81
1. Address Each Wall-Mount Unit .............. 81
2. Execute a Run Test on Each Unit ........... 82
3. Clear Unit Alarm Logs on Each Unit ....... 82
Setting Up LC6000 for Operation .................... 83
LC6000 Status Screen ............................. 83
4. Set LC Controller Date and Time ............ 83
5. Configure Sensors................................. 84
6. Enter Total Number of Units .................. 86
7. Verify Units are Online .......................... 86
8. Clear Controller Alarm Logs ................... 86
9. Complete Installation ............................ 86
Additional Information ....................................87
Menu Screens and Password Levels.................. 87
Setpoints ....................................................... 87
Calibrating Sensors ......................................... 87
FIGURES AND TABLES
Figure 1
WR Series Model Nomenclature ......... 53
Figure 2
Dimensions ...................................... 55
Figure 3
Prefilling Traps on Indoor Drain Pan
Hoses ................................................ 57
Figure 4
Hanging Front Access Panel to Allow
Access to Control Panel ..................... 57
Figure 5
Fold-Out Diverter .............................. 58
Figure 6
Downward Curved Diverter Blades ...... 58
Figure 7
View of Installed Grille ...................... 58
Figure 8
Mounting Instructions ....................... 59
Figure 9
Electric Heat Clearance ..................... 60
Figure 10 Wall Mounting Instructions ................ 60
Figure 11 Wall Mounting Instructions ................ 61
Figure 12 Common Wall Mounting Installations .. 61
Figure 13 Wire Routing .................................... 63
Figure 14
WIRING:
VAC Supply Wiring
Landing Points ................................. 63
Figure 15 Side Communication and Power Wire
Entrances (Recommended) ................ 63
Figure 16 Rear Communication and Power Wire
Entrances (Optional) ......................... 64
Figure 17 Adjusting the 230/208 VAC
Transformer ...................................... 65
Figure 18 Cool and Heat Setpoints .................... 66
Figure 19 Typical LC6000 Component Location . 67
Figure 20 LC6000 Fused Power Supply Terminal 68
Figure 21 Remote Indoor Temperature/Humidity
Sensor Installation ............................ 69
Figure 22 Additional Remote Sensor Installation .. 70
Figure 23
Smoke Detector, Hydrogen Detector
and Generator Run Connections .............71
Figure 24 Communication Wiring (Daisy Chain) .. 72
Figure 25 Communication Wiring (Alt. Method) .. 72
Figure 26 Placement of Communication Filters .. 73
Figure 27 Communication Wiring: Termination
at the Controller ............................... 74
Figure 28 Communication Wiring: Termination
at the First Wall-Mount Unit .............. 75
Figure 29 Communication Wiring: Termination
at Additional Wall-Mount Units .......... 76
Figure 30 LC6000 Controller Supply Wiring ....... 77
Figure 31 Controller Grounding Posts ................ 77
Figure 32
WIRING:
LC6000 Wiring Diagram ........ 79
Figure 33 TEC-EYE Connection to Unit Control ... 80
Figure 34 TEC-EYE Display and Interface .......... 80
Figure 35 Changing Unit Setup Values .............. 81
Figure 36 Changing Economizer Control Type ..... 81
Figure 37 Executing Run Test ........................... 82
Figure 38 Run Test Summary............................ 82
Figure 39 Run Test: Motors & Sensors ............... 82
Figure 40 Run Test: A/C Circuit ......................... 82
Figure 41 Clearing Unit Alarm Logs ................... 83
Содержание MULTI-TEC W24AAPA
Страница 3: ...Page 3 of 88 SECTION 1 MULTI TEC LC6000 INSTALLATION INSTRUCTIONS...
Страница 36: ...Manual 2100 676B Page 36 of 88 FIGURE 25 LC6000 Wiring Diagram...
Страница 46: ...Manual 2100 676B Page 46 of 88...
Страница 47: ...Manual 2100 676B Page 47 of 88 SECTION 2 WR SERIES LC6000 INSTALLATION INSTRUCTIONS...
Страница 79: ...Manual 2100 676B Page 79 of 88 FIGURE 32 LC6000 Wiring Diagram...