LIST OF NECESSARY MATERIALS/TOOLS
Additional hardware and miscellaneous supplies are needed for installation. These items are field supplied and must
be sourced before installation. This list also includes tools needed for installation.
List of Materials/Tools
• Personal protective equipment/safety devices/anti-
static wrist straps
• Supply and return grilles
• Field-fabricated sleeves (if necessary)
• Fasteners sufficient for mounting the units such as
5/16" diameter anchor/lag bolts
• 7/8" diameter washers
• Fasteners appropriate for the shelter wall
construction to attach the controller to the wall
• Commercial grade outdoor silicone sealant
• Miscellaneous hand and power tools and jobsite or
shop materials
• Lifting equipment with the necessary capacity and
rigging to safely move/install the systems
• Electrical supplies
- Various size circuit breakers for the shelter AC
breaker box (see Tables 1, 2 and 3 on pages 20,
21 and 22)
- High-voltage wire of various gauges
(see Tables 1, 2 and 3)
-
16 gauge minimum, 14 gauge maximum power
wire to connect controller to shelter power source
-
5-wire, 18 gauge shielded cable for remote
temperature and humidity sensors (2-wire, 18
gauge shielded cable for temperature-only sensors)
- Communication wire: 2-wire, 18 gauge, shielded
with drain
- 18 gauge non-shielded wire for connecting
smoke detector, hydrogen detector and/or
generator, if applicable, to controller
-
CAT 6 Ethernet cable of field-determined length
(for remote communication, if applicable)
-
2 hole grounding lug (to be used with supplied
1/4" bolts and nuts for grounding controller box)
- Miscellaneous electrical supplies including rigid/
flexible conduit and fittings, 2" x 4" junction
boxes (one per temperature/humidity sensor),
wire connectors and supports
Reference Supplemental Instructions
7960-801 for complete details.
FIGURE 1
MULTI-TEC Wall-Mount Unit Model Nomenclature
CONTROL MODULES
E – Low Ambient Control
C – Low Ambient Control
& Crank Case Heater
COIL OPTIONS
X
–
Standard
1
–
Phenolic Coated Evaporator
2
–
Phenolic Coated Condenser
3
–
Phenolic Coated Evaporator
and Condenser
P
– PLC Logic Board
E
– PLC Logic Board w/Electric Reheat
M
– PLC Logic Board w/Mechanical Dehumidification
W
36
A
A
P
A 10 5 X X X X E
MODEL SERIES
REVISION
KW
A –
Right Hand
L –
Left Hand
FILTER OPTIONS
X
–
1" Throwaway (Standard)
W
–
1" Washable
P
–
2" Pleated (MERV 8)
SUPPLY AIR OUTLET
X
–
Front (Standard)
COLOR OPTIONS
X
–
Beige (Standard)
1
–
White
4
–
Buckeye Gray
18
–
1½ Ton
24
–
2 Ton
30
–
2½ Ton
36
–
3 Ton
CAPACITY
42
–
3½ Ton
48
–
4 Ton
60
–
5 Ton
72
–
6 Ton
VENTILATION OPTIONS
B
–
Blank-off Plate
5
–
Economizer
A
–
230/208/60/1
B
–
230/208/60/3
C
–
460/60/3
D
–
240/220/50/1
VOLTS & PHASE
E
–
240/220/50/3
or 220/200/50/3
F
–
415/380/50/3
Q
–
575/60/3
Содержание MULTI-TEC W24AAPA
Страница 3: ...Page 3 of 88 SECTION 1 MULTI TEC LC6000 INSTALLATION INSTRUCTIONS...
Страница 36: ...Manual 2100 676B Page 36 of 88 FIGURE 25 LC6000 Wiring Diagram...
Страница 46: ...Manual 2100 676B Page 46 of 88...
Страница 47: ...Manual 2100 676B Page 47 of 88 SECTION 2 WR SERIES LC6000 INSTALLATION INSTRUCTIONS...
Страница 79: ...Manual 2100 676B Page 79 of 88 FIGURE 32 LC6000 Wiring Diagram...