FSN Series • User’s Guide
3. Control Panel Orientation
Control Panel Descriptions
~
If you press
CLEAR
, the appropriate register clears and a dash appears.
However, the function (store or recall) remains active, along with the
selected modules.
~
If you turn off the
STORE
or
RECALL
button prior to pressing
ENTER
,
you effectively cancel the operation, and the appropriate register returns
to its previous value.
2) Function
Section
The two buttons in the
Function Section
determine the memory function that you
want to perform. Only one button can be selected at a time.
~
To store a switcher setup in memory:
•
Press
STORE
to initiate the procedure.
•
Select the module(s) to be included in the register.
•
Enter a register number.
•
Press
ENTER
.
~
To recall a switcher setup from memory:
•
Press
RECALL
to initiate the procedure.
•
Enter a register number.
•
Press
ENTER
.
~
To cancel a “store” or “recall” function, turn the
STORE
or
RECALL
button off, prior to pressing
ENTER
.
~
To display the
Memory Menu
on the
Touch Screen
, press and hold
either
STORE
or
RECALL
.
” section on page 291
for more information.
3) Module
Section
The eight buttons in the
Module Section
select the switcher modules and
functions to be included in the selected store or recall operation. Please note:
~
Each button is a toggle — press to enable, press again to disable. The
buttons are
not
mutually exclusive.
•
For a
store
procedure, one or more modules must be selected,
and any combination can be included in the memory register.
•
For a
recall
procedure, you cannot add modules to a register
already stored, but you
can
remove modules from a recall.
~
It is not necessary to select modules for a recall procedure. When you
press
RECALL
and enter digits, the modules associated with the stored
register(s) will automatically light.
Following are descriptions of each button in the
Module Section
:
~
Press
M/E 1
to include the entire M/E 1 bank in a store procedure, or
remove the bank from a recall procedure. Using the
Memory Menu
, if
desired, you can elect to include or exclude certain sub-sections of M/E 1
in the procedure.
STORE
RECALL
Note
It is not necessary to select modules for a recall. When you
press
RECALL
and enter digits, the module buttons
associated with the stored register(s) will automatically light.
M/E 1