Maintenance / Servicing • Fan kit installation and replacement
Chap
ter 7
•
Ma
inte
nanc
e /
Servic
ing
453
Automation PC 620 User's Manual V 1.90
•
The fan connection cable must be connected to the main circuit board at the right position
(fan 1 at position 1, fan 2 at position 2, fan 3 at position 3).
•
If one or more PCI cards were previously in place, they can now be re-inserted.
•
If a slide-in drive was previously in place, it too can now be re-inserted.
•
Place the dust filter in the fan kit cover and secure with the filter clasp.
Figure 247: APC620 5PCI slots - Fan cable connection to the main board