Software • Automation PC 620 with BIOS
Chap
ter 4
•
Soft
w
are
311
Automation PC 620 User's Manual V 1.90
1.3 BIOS postcode messages
While the Automation PC 620 is booting, the following messages and errors can occur with
BIOS. These errors are signaled by different beeping codes.
Beeping code
Description
Necessary user action
1
Everything OK
-
1-2
1x long 2x short - checksum error in the ROM
BIOS updates
1-2-2-3
BIOS checksum error
BIOS updates.
1-3-1-1
Test DRAM refresh, DRAM module is not set properly.
Send industrial PC to B&R for checking.
1-3-1-3
Test 8742 keyboard controller, self test of the keyboard
controller failed.
Send industrial PC to B&R for checking.
1-3-4-1
RAM error at address xxxx
Send industrial PC to B&R for checking.
1-3-4-3
RAM error at data bit xxxx, at the lowest bit of the memory
bus
Send industrial PC to B&R for checking.
1-4-1-1
RAM error at data bit xxxx, at the highest bit of the memory
bus
Send industrial PC to B&R for checking.
2-1-2-3
ROM copyright has an error
Send industrial PC to B&R for checking.
2-2-3-1
Unexpected interrupt
Check interrupt settings in BIOS.
Table 225: BIOS postcode messages
Содержание Automation PC 620
Страница 2: ...2 Automation PC 620 User s Manual V 1 90...
Страница 4: ...4 Automation PC 620 User s Manual V 1 90...
Страница 6: ...6 Automation PC 620 User s Manual V 1 90...
Страница 204: ...204 Commissioning Connection examples Automation Panel 900 Automation PC 620 User s Manual V 1 90...
Страница 376: ...376 Maintenance servicing International certifications Automation PC 620 User s Manual V 1 90...
Страница 487: ...Appendix A Glossary Appendix A 487 Automation PC 620 User s Manual V 1 90...
Страница 488: ...488 Appendix A Glossary Automation PC 620 User s Manual V 1 90...
Страница 512: ...Index 512 Automation PC 620 User s Manual V 1 90...