46
Parameterization
15 2 1 Brake open time (OT) parameterization
First set the open time of the brake (OT). It determines the speed
of load lowering when the brake is opened.
Cable a load that is available in normal operation until just
before the winch's guide pulley.
Stutter brake switch
Gas + / "Gas–" switch
Brake open time (OT) parameterization
Press the switch "Stutter brake" towards the body and hold
the switch in this position.
The brake is alternately opened and closed again. If the load
lowering is too fast during this period, the opening time
must be reduced.
To reduce the open time, press the switch "Stutter brake"
towards the body and hold the switch in this position. Also
briefly touch the switch for "Gas +". Every time "Gas +" is
touched the open time is reduced by roughly 1/10 of a
second. As a result the load lowering is slower.
To extend the open time, press the switch "Stutter brake"
towards the body and hold the switch in this position. Also
briefly touch the switch for "Gas –". Every time "Gas –" is
touched the open time is extended by roughly 1/10 of a
second. As a result the load lowering is quicker.
After releasing the switch, the values are automatically
saved; however, they can be changed again at any time.