26
Functional Description
Application:
With "Gas +", a fixed, higher motor speed is set.
With "Gas –", a fixed, lower motor speed is set.
8 2 3
Gas adjustment
Gas continuous (GS)
The function "Gas +" is started by holding the switch in the
direction of this icon and is stopped by releasing the switch (jog
mode).
The function "Gas –" is started by holding the switch in the
direction of this icon and is stopped by releasing the switch (jog
mode).
Application:
The motor speed is controlled, for example, on the throttle rods
upwards (Gas +) or downwards (Gas –) by a lifting spindle motor
(e.g. WARNER M-Track 1 gas actuator).
For machines without mechanical gas-adjustment capability,
the Propgas control module PGS01 can be used. Depending on
the function Gas + / Gas –, the module outputs a variable DC
voltage of between 0–4.8 V to the motor control unit.
Gas simple (GE)
Can be parameterized at the factory
When tipping the switch towards this icon, the function "Gas +"
switches on the supply voltage to the "Gas +" output.
When tipping the switch towards this icon, the function "Gas –"
switches off the supply voltage to the "Gas +" output.
The function "release brake without permanent brake
release" can be parametrized at the factory.
This function is intended for winches with cable ejec-
tion in order to prevent accidental permanent brake
release and thus the complete ejection of the cable.
Furthermore, there is no time delay with this function
(duration of permanent brake release).
When pressing the "Release brake" switch in jog mode,
the brake can be released and the cable ejection can be
triggered for the duration of time the switch is actua-
ted. For complete cable ejection, you can use the func-
tion "Permanent brake release" of operating level 2.