76
•
0
•
1
•
2
•
3
configurationIndex
Index of the PRACH configuration.
For FDD: All PRACH configuration indexes
corresponding to Format 0 are supported. Refer to
Table 5.7.1-2 of 36.211.
For TDD: All PRACH configuration indexes with a
configured subframe configuration corresponding to
Format 0 and Format 4 are supported. Refer to Table
5.7.1-4 of 36.211.
Capacity Parameters:
Max Ue Num
The maximum number of concurrent users.
Range: 1 to 32
maxCsgMembers
The maximum number of CSG members.
Range: 1 to 32
resourceReservedForExistingUsers Reserved UE resource
Range: 0 to 100
5.5.2.4
Log Config
Refer to Figure 5-49 and Table 5-31 for a description of the
Log Config
parameters. For the
phyTrackSubsystemConfig
fields, click on the display icon
of a line to display the
configuration fields.
After entering the parameters, select
Save
to retain the configuration.
Figure 5-49: Log Config