46
For each type of neighboring eNB, you will first add the neighbor frequency settings via the
Neigh Freq List
, and then you will add the cell information associated to the frequencies via
the
Neigh Cell List
.
You can configure the
Neigh Cell List
for both inter-frequency (between different frequencies)
and intra-frequency (within the same frequency) neighboring eNBs. For inter-frequency cells,
you must add the neighbor inter-frequency settings in the
Neigh Frequency List
before you try
to add the neighbor inter-frequency cell (eNB) information. Conversely, if you need to delete
a neighbor inter-frequency record, you must first delete the neighbor inter-frequency cells
(eNBs) associated to it.
For an intra-frequency neighbor cell, meaning a neighbor eNB operating on the same
frequency as the eNB you are configuring, you do not need to configure the
Neigh Freq List,
but you do need to configure the
Neigh Cell List
.
5.5.1.3
LTE Freq/Cell
Using the
LTE Freq/Cell
sub-menu, you can configure parameters related to how adjacent eNBs
operating with LTE technology work with the Baicells Neutrino eNB that you are configuring.
In other words, you will define for the Neutrino eNB how to coordinate with any neighboring
LTE eNBs. Up to 8 LTE neighbor frequencies and 32 LTE neighbor cells can be configured.
5.5.1.3.1
Neigh Freq List
1.
In the eNB GUI go to LTE Setting > LTE Freq/Cell (Figure 5-23).
Figure 5-23: LTE Freq/Cell
2.
Under
Neigh Freq List
, click on the
Add
icon
to add the neighboring LTE eNBs’
frequencies (up to 8). The fields are shown in Figures 5-24 and 5-25, and described in
Table 5-13. Click on
Save
after setting the values.
Содержание Neutrino-224
Страница 1: ...Neutrino 224 Indoor 2x125mW FDD TDD eNodeB Installation Guide December 2018 Version 1 7...
Страница 20: ...20 Figure 4 7 FDD eNB GUI Home Page Figure 4 8 TDD eNB GUI Home Page...
Страница 47: ...47 Figure 5 24 LTE Neigh Freq Settings 1 of 2 Figure 5 25 LTE Neigh Freq Settings 2 of 2...
Страница 64: ...64 Figure 5 38 Cell ReSelection Parameter Figure 5 39 Additional Measurement Parameter...