40
Figure 5-18: NTP
Table 5-12: NTP
Parameter Name
Description
onBoot
Enable or disable the NTP function
Port
Port number of the master NTP server. Must be consistent with
the other end. Range: 1 to 65535
Server1
Domain name or IP address of the master NTP server. Must be
consistent with the other end.
Server2
Domain name or IP address of the slave NTP server. Must be
consistent with the other end.
Server3
Domain name or IP address of the slave NTP server. Must be
consistent with the other end.
5.4.2
Upgrade
The
Upgrade
menu shown in Figure 5-19 provides the ability for you to upgrade an eNB’s
firmware, perform a firmware version rollback (downgrade), or install patches to the current
firmware running on the eNB. Most version changes will cause the eNB to reboot, interrupting
service to any users connected to the eNB. Plan on executing such changes during a time when
there is likely to be few or no active users.
Содержание Neutrino-224
Страница 1: ...Neutrino 224 Indoor 2x125mW FDD TDD eNodeB Installation Guide December 2018 Version 1 7...
Страница 20: ...20 Figure 4 7 FDD eNB GUI Home Page Figure 4 8 TDD eNB GUI Home Page...
Страница 47: ...47 Figure 5 24 LTE Neigh Freq Settings 1 of 2 Figure 5 25 LTE Neigh Freq Settings 2 of 2...
Страница 64: ...64 Figure 5 38 Cell ReSelection Parameter Figure 5 39 Additional Measurement Parameter...