52
5.5.1.4.1
Neigh Freq List
1.
In the eNB GUI go to LTE Setting > 3G Freq/Cell (Figure 5-27).
Figure 5-27: 3G Freq/Cell
2.
Under
Neigh Freq List
, click on the
Add
icon
to add the neighboring 3G eNBs’
frequencies (up to 12). Each field is described in Table 5-15. Click on
Save
after setting
the values.
Table 5-15: Neigh Freq List
Parameter Name
Description
utraCarrierArfcn
Frequency point of the neighbor frequency
qRxLevMin
Minimum access level. Only if the received signal power
measured by the UE is higher than this threshold, can the UE
connect to this cell.
qQualMin
The threshold for the lowest access.
Range: -24 to 0.
Reselection Priority
Priority of the reselection to cells at this frequency
threshXHigh
Reselection threshold for higher priority inter-band
frequencies. This parameter represents the access threshold
level at which the UE will leave the serving cell and reselect
another cell at the target frequency, given that the target
frequency cell has a cell reselection priority higher than the
serving one
threshXLow
Reselection threshold for lower priority inter-band
frequencies.
This parameter represents the access threshold level at which
the UE will leave the serving cell and reselect another cell at
the target frequency, given that the target frequency cell has
an absolute priority lower than the serving one.
pMaxUtra
Maximum transmit power a UE is allowed to use in the uplink.
The purpose is to limit the transmit power of UEs within this
cell.
threshServingHighqR9
High RSRQ threshold of priority reselection.
Range: 0 to 31.
Содержание Neutrino-224
Страница 1: ...Neutrino 224 Indoor 2x125mW FDD TDD eNodeB Installation Guide December 2018 Version 1 7...
Страница 20: ...20 Figure 4 7 FDD eNB GUI Home Page Figure 4 8 TDD eNB GUI Home Page...
Страница 47: ...47 Figure 5 24 LTE Neigh Freq Settings 1 of 2 Figure 5 25 LTE Neigh Freq Settings 2 of 2...
Страница 64: ...64 Figure 5 38 Cell ReSelection Parameter Figure 5 39 Additional Measurement Parameter...