62
Options:
SameAsTriggerQuantity
Both
maxReportCells
Maximum number of IRAT cells that can be included in a
measurement report.
Range: 1 to 8
reportInterval
Report Interval of the periodic measurement report, in
milliseconds.
Options: 120 (default), 240, 480, 640, 1024, 2048, 5120,
10240, 60000, 360000, 720000, 1800000, 3600000 ms
reportAmount
Number of times an IRAT measurement report is sent.
Options: 0,1,2,4,8,16,32
measQuantityUtra
Indicates the measurement quantity used for UTRA event
measurement evaluation or the measurement quantity to be
included in the UTRA measurement report.
Options:
CPICH_RSCP
CPICH_EcNo
UTRAThresholdRsCP
RSCP threshold to be used in UTRA measurement report
triggering condition for event B2, per CPICH_RSCP in TS 25.133
[29] for FDD and P-CCPCH_RSCP in TS 25.123 [30] for TDD.
Range: -5 to 91
UTRAThresholdEcNO
Energy per Chip Noise (EcNo) threshold to be used in UTRA
measurement report triggering condition for event B2, per
CPICH_Ec/No in TS 25.133 [29] for FDD. The field is not
present for TDD.
Range: 0 to 49
GERANThreshold
Threshold to be used in the GERAN measurement report
triggering condition for event B2. The actual value is IE value –
110 dBm. Refer to 3GPP 36.331 6.3.5.
Range: 0 to 63
Figure 5-32: A3 Event Threshold
Содержание Neutrino-224
Страница 1: ...Neutrino 224 Indoor 2x125mW FDD TDD eNodeB Installation Guide December 2018 Version 1 7...
Страница 20: ...20 Figure 4 7 FDD eNB GUI Home Page Figure 4 8 TDD eNB GUI Home Page...
Страница 47: ...47 Figure 5 24 LTE Neigh Freq Settings 1 of 2 Figure 5 25 LTE Neigh Freq Settings 2 of 2...
Страница 64: ...64 Figure 5 38 Cell ReSelection Parameter Figure 5 39 Additional Measurement Parameter...