67
Table 5-21: eNodeB Settings
Parameter Name
Description
eNodeb Name
Name the eNB you are configuring, using 0-48 characters
comprised of letters, numbers, and special characters.
CellType
Options: 0 or 1
s1ConnectionMode
S1 connection to MME.
Options: one or all
relOfMme
S1 connection protocol version.
Options: 0, 1, or 2
accessMode
Options:
•
ClosedAccess
•
HybridAccess
•
OpenAccess
5.5.1.7.3
GAP Setting
Refer to Table 5-22 for a description of the
GAP Setting
fields.
Table 5-22: GAP Setting
Parameter Name
Description
siGapEnable
Enable or disable the GAP function
eutranGapOffsetType
GAP type of the LTE measurement.
Options:
•
0 (gp0)
•
1 (gp1)
geranGapOffsetType
GAP type of the GSM measurement.
Options:
• 0 (gp0)
• 1 (gp1)
cdma2000GapOffsetType GAP type of the CDMA measurement.
Options:
• 0 (gp0)
• 1 (gp1)
triggerQuantityForBlock Trigger quantity of the mobility measurement of the UE
caused by the cell operation, for example, cell block, load
balance, etc.
a4ThresholdRsrpForBlock RSRP threshold used by the A4 event when there is a mobility
measurement of the UE caused by the cell operation, for
example, cell block, load balance, etc.
a4ThresholdRsrqForBlock RSRQ threshold used by the A4 event when there is a mobility
measurement of the UE caused by the cell operation, for
example, cell block, load balance, etc.
Содержание Neutrino-224
Страница 1: ...Neutrino 224 Indoor 2x125mW FDD TDD eNodeB Installation Guide December 2018 Version 1 7...
Страница 20: ...20 Figure 4 7 FDD eNB GUI Home Page Figure 4 8 TDD eNB GUI Home Page...
Страница 47: ...47 Figure 5 24 LTE Neigh Freq Settings 1 of 2 Figure 5 25 LTE Neigh Freq Settings 2 of 2...
Страница 64: ...64 Figure 5 38 Cell ReSelection Parameter Figure 5 39 Additional Measurement Parameter...