2-18
Installation on metal pipe (2)
Introduction
The installation method described in this section corresponds to the following combination
of pipe and grounding ring materials. For the installation method corresponding to any other
combination, refer to the table on page 2-13.
Pipe material: metal
Grounding ring material: other than SUS material
Required accessories
The following parts are required. No gaskets are necessary since PTFE gaskets are provided.
Through-bolts and nuts
Centering guide bushings
Installation procedure
Install the detector as shown in Fig. 2-12. See Table. 2-1 on page 2-8 for the appropriate
fastening torque.
To use rubber gaskets for a low fastening torque, refer to page 2-22.
CAUTION
Please note that the use of an additional gasket besides the existing PTFE gasket may result in
leakage (see Fig. 2-13).
PTFE gasket
Grounding ring
Lining
PTFE gasket
Grounding ring
Lining
Gasket
Fig. 2-12. Installation using Non-SUS
material grounding ring and metal pipe
Fig. 2-13. Example of incorrect installation