8.8 MOTOR TUNING
Motor tuning is the process of motor parameter definition. No rotation of motor required in tuning
process.
When entering Tuning Menu, “PRESS UP ARROW for TUNING PROCESS” message displays on the screen.
If K1 and K2 motor contactor controlled by control panel, hold activated during tuning process. By up
arrow, tuning process will start and after 30 seconds, system completed process if no fault occurs. After
process, release motor contactors if controlled by control panel.
Set these parameters before tuning process:
[M01]-Motor Type
[M02]-Motor Speed
[M03]-Motor RPM
[M04]-Motor Frequency
[M05]-Motor Current
[M06]-Motor Voltage
[M07]-Motor Cos Value
[M08]-Motor Poles
[M10]-Encoder Pulse
[M18]-Encoder Type
*** In synchronous motor, hold activated ENB input during tuning process.
F/7.5.5.02.95 R:1
42
AE-LIFT