Rescue Function
AEL05
AEL07
AEL11
AEL15
AEL22
UPS-PowerCircuit
1500 VA
2000 VA
3000 VA
4000 VA
5000 VA
UPS-Control Circuit
1000 VA
Battery-Power Circuit
5 x 7Ah
60V DC
5 x 12Ah
60V DC
* Selection of battery, UPS and cable is made according to the parameter of Rescue Direction [C18] is
set to EASY DIRECTION.
** Minimum level of battery voltage must be 60V DC when battery is using for rescue operation
supplier and [C18] Rescue Direction is “Command Direction”.
Braking Resistor
AEL05
AEL07
AEL11
AEL15
AEL22
Resistor Value
72 Ω
60 Ω
40 Ω
30 Ω
20 Ω
Minimum Power
(1)
1200 W
1500 W
2200 W
3000 W
4400 W
(1)
Minimum preferred power of resistor listed in table. Use higher powered resistor than listed for long
period travel applications.
Line Filter (EMC)
AEL05
AEL07
AEL11
AEL15
AEL22
Current Capacity
20 A
20 A
30 A
40 A
60 A
F/7.5.5.02.95 R:1