8.1.1.2 Speed Input Precedence
Precedence of active speed inputs are detailed below.
1) Device drives motor at VR speed in rescue operation mode.
2) Device drives motor with the highest active input reference speed. When V1 and V4 inputs are active
both, If V4 speed is higher than V1 speed, system accepts V4; otherwise sytems accepts V1 as reference
speed. ([S19] = 0)
8.1.1.3 Speed Qualification
S01
V1 SPEED (CREEPING SPEED)
Min: 0.01 m/s
Max: 5 m/s
Default: 0.07 m/s
Creeping speed of motor.
S02
V2 SPEED (INSPECTION SPEED)
Min: 0.01 m/s
Max: 5 m/s
Default: 0.3 m/s
Inspection mode speed of motor.
S03
V3 SPEED (MIDDLE SPEED)
Min: 0.01 m/s
Max: 5 m/s
Default: 0.5 m/s
Middle speed of motor if more than one travel speed required.
S04
V4 SPEED (NORMAL SPEED)
Min: 0.01 m/s
Max: 5 m/s
Default: 1 m/s
Travel speed of motor.
S05
V5 SPEED (HIGH SPEED)
Min: 0.01 m/s
Max: 5 m/s
Default: 1 m/s
High speed of motor. (if required)
S06
V6 SPEED (RELEVELING SPEED)
Min: 0.01 m/s
Max: 5 m/s
Default: 0.03 m/s
Releveling speed of lift.
S07
VR SPEED (RESCUE SPEED)
Min: 0.01 m/s
Max: 0.20 m/s
Default: 0.05 m/s
Motor speed in rescue operation. System does not accepts any speed input and use VR speed as
reference speed.
S08
START MODE
Min: 0
Max: 2
Default: 0
Do not change this parameter.
F/7.5.5.02.95 R:1
20
AE-LIFT