SECTION 2-TECHNICAL SPECIFICATIONS
2.1 ELECTRICAL SPECIFICATIONS
AE-Lift motor driver technical specifications and maximum capacities are listed in Table 2.1. Device can
be damaged if loaded more than maximum capacities or installed without proper auxiliary units. For this
reason, select device model according to motor current, voltage and other specifications and select
other parts in control panel according to values listed in Table 3.1.
Table 2.1 Technical Specifications
MODEL
AEL05
AEL07
AEL11
AEL15
AEL22
Nominal Motor Power
5.5 kW
(7.5 hp)
7.5 kW
(10 hp)
11 kW
(15 hp)
15 kW
(20 hp)
22 kW
(30 hp)
Nominal Output Current
14 A
18 A
25 A
32 A
45 A
Maximum Current
Allowed Time
28 A
5 s
36 A
5 s
50 A
5 s
64 A
5 s
90 A
5 s
Control Circuit Input Voltage
1-Phase 100V.......240V AC 50/60 Hz +- %5
Nominal Power Input Voltage
3-Phase 340V........420V AC 50/60 Hz +- %5
Nominal Power Output Voltage
3-Phase 0V......420V AC 0......100 Hz
Carrier Frequency
6....16 KHz
Braking Resistor
Minimum Power
(1)
72 Ω
1200 W
60 Ω
1500 W
40 Ω
2200 W
30 Ω
3000 W
20 Ω
4400 W
Cooling
2 Fans
3 Fans
Weight
7 kg
7 kg
8 kg
12 kg
12 kg
(1)
Minimum preferred power of resistor listed in table. Use higher powered resistor than listed for long
period travel applications.
F/7.5.5.02.95 R:1
2
AE-LIFT