98
AMWorks Software Installer/User Guide
AMWorks software hangs during firmware update
If the matrix switch is powered down or the network is lost during the ftp portion of a firmware
update, the AMWorks software may appear to hang. There will be a delay before the AMWorks
software becomes responsive again.
Table 1.12: Troubleshooting - AMWorks Software Hangs During Firmware Update
Cause
Recommended Solution
The matrix switch was powered down or the network
connection was lost during a firmware update.
Terminate and restart the application. Once the
network problem is fixed, start a new firmware update.
See
Updating Firmware
on page 74 for
more information.
Synchronization status indicator turns red
When the synchronization status indicator turns red, the AMWorks software may be “out of sync.”
The causes and solutions for the out-of-sync state are shown below.
Table 1.13: Troubleshooting - Synchronization Status Indicator Turns Red
Cause
Recommended Solution
A new AMX switch has been manually added to the
system or a new AMX switch has been
automatically discovered.
Perform another synchronization to return the system
to a synchronized state.
An existing AMX switch has been removed from
the system.
Perform another synchronization to return the system
to a synchronized state.
The system is newly installed and has not yet
been synchronized.
Perform an initial synchronization to complete
the installation.
You have set up user and/or server groups on the
system using the AMWorks software, but have made
user access rights changes from an AMX user station
OSCAR interface.
Perform another synchronization to return the system
to a synchronized state.
NOTE:
If you have set up user and/or server groups,
use only the AMWorks software to administer
the system.
You have made database changes from the AMWorks
software (for example, added or removed users) and
a network error prevented your changes from
propagating to the distributed AMX
switch configuration.
Perform another synchronization to return the system
to a synchronized state.
You have made database changes from the AMWorks
software or from an AMX user station OSCAR
interface and one or more of your configured AMX
switches was not powered at the time.
Perform another synchronization to return the system
to a synchronized state.
Содержание AMWorks
Страница 1: ...Installer User Guide AMWorks...
Страница 2: ......
Страница 4: ......
Страница 12: ...4 AMWorks Software Installer User Guide...
Страница 16: ...8 AMWorks Software Installer User Guide...
Страница 22: ...14 AMWorks Software Installer User Guide...
Страница 50: ...42 AMWorks Software Installer User Guide...
Страница 62: ...54 AMWorks Software Installer User Guide...
Страница 68: ...60 AMWorks Software Installer User Guide...
Страница 86: ...78 AMWorks Software Installer User Guide...
Страница 112: ......