![Avital AviStar 3300 Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/avital/avistar-3300/avistar-3300_installation-manual_3032354049.webp)
© 2000 Directed Electronics, Inc. Vista, CA
49
■
Closing the door triggers the system, but opening the door does not:
Have you correctly identified the type of door switch system? This happens often when the wrong door input has
been used. (See
Door Lock Harness Wire Connection Guide
section of this guide.)
■
System will not passively arm until it is remotely armed and then disarmed:
Are the door inputs connected? Is the H1/6 blue wire connected to the door trigger wire in the vehicle? Either
the H1/5 green or the H1/7 violet should be used instead. (See wiring diagrams.)
■
Door input does not respond with the progressive trigger, but with immediate full alarm:
Does the Status LED indicate that the trigger was caused by the shock sensor? (See
Diagnostics
section of this
guide.) The shock sensor, if set to extreme sensitivity, may be detecting the door unlatching before the door
switch sends its signal. Reducing the sensitivity can solve this problem.
■
The Valet®/Program switch doesn't work.
Is it plugged into the correct socket? See
Plug-In LED and Valet®/Program Switch
section of this guide.
■
Status LED doesn't work.
You've probably guessed already, but here goes: Is it plugged in? (See
Plug-In LED and Valet®/Program Switch
section of this guide.) Is the LED plugged into the correct socket?
■
Door locks operate backwards.
This unit has easily-reversed lock/unlock outputs. Recheck wire connections to see if you have reversed these.
■
The remote start will not activate.
1. Check the harnesses and their connections. Make sure that the harnesses are completely plugged into the
remote start module. Make sure there are good connections to the vehicle wiring.
2. Check voltage and fuses. Use a meter to check for voltage between the red wire in the 5-pin ribbon harness
and the black ground wire. If you have less than battery voltage, check the 3A and both 30A fuses on the
relay satellite. Also make sure that the ground wire connects to a good chassis ground point.
3. Check diagnostics. The diagnostics will tell you which shutdown is active or not connected.
■
The remote start will activate, but the starter never engages.
1. Check for voltage on the purple starter wire two seconds after the remote start becomes active. If there is
voltage present, skip to Step 4. If there is not voltage present, advance to Step 2.
2. Check the 30A fuses.
3. Check diagnostics. If the gray/black wire is detecting ground upon activation, the starter will not crank.
4. Make sure the purple starter wire is connected on the starter side of the starter kill/anti-grind relay.
5. Does the vehicle have an immobilizer? Some immobilizer systems will not allow the vehicle to crank if
active.
remote start troubleshooting