46
© 2000 Directed Electronics, Inc. Vista, CA
shutdown diagnostics
To perform shutdown diagnostics:
1. With the ignition OFF, press and hold the Valet/Program button.
2. Turn the ignition ON and then back OFF while holding the Valet/Program button.
3. Release the Valet/Program button.
4. Press and release the Valet/Program button. The LED will report the last shutdown for one minute or until
the ignition is turned on.
rapid resume logic
The Rapid Resume Logic feature ensures that when the security system is powered back up after power has been
disconnected, the system will resume the same state it was in before power was lost. For example, if power is
disconnected during a full trigger sequence, the system will still be in the full trigger sequence when power is
reconnected to the unit. If power is disconnected while the unit is disarmed, it will still be disarmed when power
is restored.
LED FLASHES
SHUTDOWN MODE
One
Timed out
Two
Over-rev shutdown
Three
Low or no RPM
Four
Transmitter shutdown (or optional push-button)
Six
(-) Shutdown (H3/3 GRAY) or (+) Shutdown (H3/4 BROWN)
Seven
(-) Neutral safety shutdown (H3/6 BLACK/WHITE)
Eight
Wait-to-start timed out