![Avital AviStar 3300 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/avital/avistar-3300/avistar-3300_installation-manual_3032354042.webp)
42
© 2000 Directed Electronics, Inc. Vista, CA
2-8 DOUBLE PULSE UNLOCK ON/OFF:
Some vehicles require two pulses on a single wire to unlock the doors.
When the double pulse unlock feature is turned on, the BLUE H4/C wire will supply two negative pulses instead
of a single pulse. At the same time, the GREEN H4/A wire will supply two positive pulses instead of a single pulse.
This makes it possible to directly interface with double pulse vehicles without any extra parts.
2-9 FACTORY ALARM DISARM WITH CHANNEL 2:
In the default setting the H2/2 factory alarm disarm output
will disarm the factory alarm system any time the button(s) controlling Channel Two is pressed.
2-10 CHANNEL 4 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED/SECOND UNLOCK
OUTPUT:
Channel Four can be programmed for these output configurations. The unit is set to the default valid-
ity output. To change the configuration, use the two-chirp setting to toggle through the different configurations.
(Refer to the H2/1 VIOLET/BLACK wire description in the
Secondary Harness Wire Connection Guide
section of this
manual.)
3-1 ENGINE CHECKING ON/OFF:
In the default setting the remote start will monitor either the vehicle's tach
wire or voltage depending on the programming of feature 3-2. If programmed OFF the vehicle will crank for the
programmed crank time (feature 3-5) and will not verify with tach or voltage that the car is running. In the OFF
setting, if the vehicle fails to start, the ignition can stay on for the entire run duration. Using tach or voltage
check is always recommended if possible.
3-2 CHECKING TYPE TACH/VOLTAGE:
Selects the method of engine monitoring. If set to TACHOMETER the unit
will reference the learned tach signal to disengage the starter. In addition it will monitor the RPM and shut down
if the engine RPM is too high or too low. When set to VOLTAGE, the unit will crank the starter for the programmed
time and then attempt to sense that the engine is running by detecting an increase in voltage. The threshold
for the voltage check is selectable in feature 3-6.
3-3 RUN TIME 12, 24, 60 MINUTES:
Selects the time in minutes that the system will operate the engine
until the system "times out". This is the maximum operation period and the system may be shut down
using a shutdown at any time. Using the Bitwriter, the run time can be programmed for any duration from 1-60
minutes.
3-4 PARKING LIGHTS FLASHING/CONSTANT:
In the default setting, the unit will flash the vehicle's parking
lights (if connected) while remote started. The constant setting will turn the parking lights on solid for the entire
run duration.
3-5 CRANK TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 SECONDS:
If the unit is programmed for no engine
checking or voltage sense, the crank time must be set to the appropriate duration. The default setting is 0.6
second. If a different crank time is desired, select feature 3-5 and select either 0.6 second by using the one-
chirp setting or toggle through the higher settings by using the two-chirp settings.
menu #3 - remote start options