card (and its MY expansion card slot) will be associated with two virtual
HA devices—16 channels total. In MY8 mode (88.2/96kHz), each 6416Y2
card installed is associated with a single virtual HA device (8 channels). Not
all sample rates are available on every Yamaha console. Refer to the table
above.
Only active Pro64 preamp channels can be controlled remotely; any remote
control commands sent from a Yamaha console to inactive 6416m channels
will be ignored. As with the RCI/MCS, the 6416Y2 must be set to the same
Control Group as all 6416m Mic Input Modules to be controlled. The Control
Group is assigned using the internal DIP switches on the 6416Y2 card, and a
6416Y2 card must always be part of a Control Group when using m‑control; it
cannot be set to the “off” Control Group as the 6416m and RCI can.
m-control Remote Control Settings on the 6416Y2
On the front panel of the 6416Y2 card, set DIP switch #10 to the down position
to enable m‑control.
Note that even though multiple 6416Y2 cards can be installed in a Yamaha
digital device, only one 6416Y2 card needs to be set to provide remote
control messages from the Yamaha device to the Pro64 network.
RS–232/422
STEREO LINK
6416
Y2
B
A
ON
CTL
CLK
AUTO
ERR
1 2 3 4 5 6 7 8 9 10 11 12
DIP switch #10 in the down position enables console remote control. (DIP
switch handles are shown in black.)
Once remote control is enabled, DIP switch block SW3 (internally) is used to
configure the m‑control remote control parameters. The A‑Net Slots that are
controllable from a particular Yamaha device are defined by the Channel/Slot
Control DIP switches, which are DIP switches number 1 through 4 on block
SW3. This feature allows the user to choose a specific range of the Pro64
network to control from a particular console.
Any combination of the Pro64 Slot banks can be activated for control.
Channel/Slot Control settings are independent of the Slot ranges used
for A‑Net Transmit and A‑Net Receive as well as for the individual channel
activation settings for audio being sent from the console into the Pro64
network; both groups of settings must be properly configured for successful
61
m
-
Control