Only one device in a Pro64 network can be designated as the Control Master.
Here, a Pro64 I/O module is shown.
Setting Control Master Status
Setting the 6416Y2 to be the network Control Master is done using the DIP
switches found on the front panel. The Control Master is set with switch
12, found in the same DIP switch block as the Stereo Link section of the
interface.
RS–232/422
STEREO LINK
6416
Y2
B
A
ON
CTL
CLK
AUTO
ERR
1 2 3 4 5 6 7 8 9 10 11 12
DIP switch 12 (shown in black) is used to set the Control Master status for a
6416Y2 card.
Move DIP switch 12 to the down position to make the 6416Y2 card the Pro64
network Control Master.
P
N
ote
:
When a 6416Y2 card is set to be Control Master, it is automatically
set to be the Clock Master. The clock comes from the Yamaha
device in this case.
21
C
ontrol
m
aster