clearly defined directional needs such as a 64 x 16 digital snake.
Although the Pro64 network can operate at sample rates higher than 96kHz,
Yamaha devices cannot. The Pro64 176.4 and 192kHz sample rates are not
available when using a 6416Y2 card in a Pro64 network.
MY8 and MY16 Modes
Switch block SW8 contains the setting for Yamaha’s MY8 and MY16 Modes.
MY16 Mode provides 16‑channel operation at 44.1/48kHz sample rates, while
the MY8 Mode provides 8‑channel operation when using higher sample rates
(88.2/96kHz) or when installing the 6416Y2 card in MY8‑only devices such as
the PM1D digital console at 48kHz.
Set DIP switch #10 in block SW8 to the up position (as seen in the diagram
above) for 16‑channel operation at 44.1/48kHz.