Set The Network Mode
Every Pro64 network has three operational modes. Auto Mode allows 64
active total channels at 48kHz, while Manual Mode provides 64x64 channels.
Managed Mode requires a computer for control, and is used for firmware
updates, etc.
The network mode is set on switch block SW9, and is only required to be set
when a 6416Y2 card is used as a Control Master. DIP switch #1 in block SW9
selects Auto Mode in the down position or Manual Mode in the up position.
SW7
SW8
SW3
SW9
SW4
SW1
SW2
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
ON
ON
ON
ON
ON
ON
Network Mode
Manual
Auto
MY16
MY8
The first DIP switch in block SW9 sets the network to Auto Mode when in the
down position.
Auto Mode provides 64 total channels/Slots at 44.1 or 48kHz, and 32 total
channels/Slots at 88.2 or 96kHz. Cables can be connected to any available
A‑Net port.
Manual Mode provides 64x64 total channels/Slots at 44.1 or 48kHz, and
32x32 total channels/Slots at 88.2 or 96kHz. The user must connect cables
to specific A‑Net ports and route data to/from them as required by the
application. Manual Mode is ideal for high channel count systems that have
48