A‑Net Transmit Settings
Port A
DIP Switch 2
DIP Switch 3
off
off
Port B
on
off
Ports A and B
off
on
Not supported
on
on
A-Net Receive Settings (Manual Mode)
The 6416Y2 can receive A‑Net data from the Pro64 network from Port A
or Port B when the network is running in Manual Mode. (This setting does
not apply when the network is operating in Auto Mode; both ports supply
identical data.) Use DIP switch 4 to direct A‑Net data from a specific 6416Y2
port to the Yamaha device.
A‑Net Receive Settings
Port A
DIP Switch 4
on
Port B
off
A-Net Transmit Base Slot Settings
The 6416Y2 card can transmit its activated channels to an 8‑channel (MY8
Mode) or 16‑channel (MY16 Mode) block of slots within the Pro64 network.
Switches 5 and 6 are used to determine where in the Pro64 network activated
channels from the Yamaha device should be sent. Base Slot refers to the first
channel number in a group of 8 or 16 channels.
A‑Net Transmit Base Slot Settings
MY16 Mode
DIP Switch 5
DIP Switch 6
MY8 Mode
Slots 1-16
off
off
Slots 1-8
Slots 17-32
on
off
Slots 9-16
Slots 33-48
off
on
Slots 17-24
Slots 49-64
on
on
Slots 25-32
Note that when running the Yamaha device or Pro64 network at sample rates
higher than 48kHz, only Slots 1‑32 are available.
44
diP s
witCh
f
unCtions