Note: NC input has to be enabled by using dipswitch 6. If the NC input is not used, dipswitch 6 must be in ON
position. It is possible to use both the NC input and the magnet, in order to control the opening of a window and
the movement of its roller blind simultaneously. The alarm signal will be generated by opening the window or by
moving the roller blind.
The transmission of an alarm state is displayed by the LED on the detector body. The table below shows all
possible uses of an AF913R detector and its corresponding location.
USE
LOCATION
Protection
of doors and windows
Fix the magnet (supplied with the device) to the door or the window to be
protected and place the AF913R detector on the frame. If desired, select the
end of alarm function by using dipswitch 3:
ON = end of alarm enabled
OFF = end of alarm disabled
The anti-shock protection can be enabled by means of dipswitch 4:
ON = anti-shock enabled
OFF = anti-shock disabled
Adjust then the pulse counts shown in figure 4 to produce a shock alarm
after the chosen number of impulses.
Protection of roller shutters, walls
(external connection of inertial or
cord detectors)
Enable the NC input by using dipswitch 6. Connect the output contact (NC)
of a vibrating inertial detector or a cord detector for roller shutter protection
to the NC input of the AF913R detector s terminal board. Adjust the pulse
count as shown in fig. 4 to produce an alarm after the chosen number of
pulses.
Technical alarms (external
connection of detectors for
technical alarms)
Connect the output contact of a detector for technical alarms to the terminal
board. We suggest using the NO input which disables the pulse count
automatically.
Moreover, the following alarms are provided:
Tampering alarm. At any moment by opening the enclosure, the tampering alarm is transmitted by the
corresponding micro-switch. By means of another micro-switch placed on the back of the card, the detector
transmits also the removal alarm. The removal alarm can be enabled or disabled by means of dipswitch 5 (see
figure.
Alarm of discharged battery. 3 beeps produced by the detector (at each alarm transmission) indicate that the
battery needs to be replaced over one month before its complete discharge.
For installation, open the detector by levering on the fastening ring by means of a screwdriver. If the intrusion
protection is used, fasten the detector body on the wall or the frame by means of screws. Use silicone and not bi-
adhesive tape if it is installed on glass.
The sequence of programming is the same as for the AF968R volumetric detectors. Dipswitch 3 must be
programmed before carrying out the programming sequence of the detector. If the function of dipswitch 3 is
changed, the programming sequence of the detector must be repeated. Programming of dipswitches 1, 2 and 4
can be changed without repeating programming.
Note: in order to use the multi-function perimeter detector to connect a detector for technical alarms
to the control panel by radio, the detector must be programmed on the 24H TECH ALARMS channel
To delete the detector, follows the same procedure as detector AF968R.