58
The AF921 control panel allows to store up to 99 radio codes coming form the AVE detectors. For programming,
proceed as follows:
Select menu EXTRAS followed by
;
Select menu ALARM A or B or C followed by ;
ZONE A OUT DOOR ALARM n., will be displayed. Choose the desired system configuration by pressing keys
, and confirm by pressing
( See section: Choice of the system configuration
The first available position PERIP. UNIT A01 will be displayed, confirm with ;
At this point, if the input is to be delayed press key 1 (IN Y
DELAY) the input will be instantaneous by default
(IN N
DELAY), while if function AND is to be enabled press 2 ( AND Y ) to enable the alarm signal only if the
two selected detectors go into alarm within 30 seconds, the function will be disabled by default ( AND N );
Note: function AND disables the INPUT DELAY function (IN DEL. ) and vice versa.
Confirm the desired configuration by pressing ;
If the INPUT DELAY function has been enabled,DELAY_ _ SEC will be displayed, set the delay by using
number keys.
If the AND function has been enabled PERIP UNIT A01/1 INSERT BATTERY will be displayed; upon inserting
the battery the detector will be stored; PERIP UNIT A01/2 INSERT BATTERY will be displayed, insert the
battery of the detector in AND.
If none of the two functions is enabled PERIP UNIT A01 INSERT BATTERY will be displayed; upon inserting
the battery the detector is stored and the summary of the set configuration is displayed;
By confirming with
LABEL A01 will be displayed, insert the identification name of the detector and confirm by
pressing ;
Once programming is over, press ESC;
Note: the label of each detector is stored in the event history file at every alarm.
Note: The control panel will emit a beep for confirmation. It will emit three beeps if the procedure has not been
successful.
The AF921 control panel allows to delete one of the stored detectors individually. For deletion, proceed as follows:
Select menu EXTRAS followed by
;
Select menu ALARM GROUP at which the detector to be deleted belongs and confirm by pressing ;
OUT DOOR ALARM n., will be displayed, confirm by pressing ;
Select the detector by using keys , confirm with
and press CANC;
DELETE? will be displayed , confirm with ;
The control panel will emit a beep for confirmation. It will emit three beeps if the procedure has not been
successful .