TEST FUNCTION
The AF921 control panel allows to make a system test at any moment without enabling the sounders:
Control panel TEST
Insert the user code (or installer code) followed by on the control panel. The following mention will be displayed:
CONTROL PANEL TEST:. By confirming with
EMPTY LIST will be displayed. Test the system functionality by
operating each detector gradually: a BEEP will be heard and each detector in alarm will be displayed. These TEST
alarms are stored and can be checked by pressing
.
Warning: upon exiting from the TEST state, the stored data reset automatically.
One test at least is recommended
every year.
Warning: to test volumetric detectors correctly, free the protected rooms from people or animals for 3 minutes at
least before generating an alarm by entering the zone. To test the protected zone, set each detector to the TEST
mode (refer to the related instructions).
Note: in TEST mode, sounders are disabled ( useful function to change batteries without generating tampering
alarms).
Telephone transmission TEST
Insert the user code (or installer code) followed by on the control panel. The following mention will be displayed:
CONTROL PANEL TEST:. By inserting DIALLER TEST will be displayed, confirm with , insert the telephone
number to be called and confirm the display suggestions. At the end press ESC to exit.
Note: All the operations carried out during the test are stored in a 50-event history file that can be read by pressing
keys
.