OPERATION
Choice of the system configuration
AF921 allows to have two different system protection solutions:
3. traditional alarm system. By programming the zones (A-B-C) in this way, the general alarm will be
activated upon detection of the intruder.
4. pre-alarm system. It is obtained by programming a zone (A-B-C) as an external zone. The detectors
connected and located outside the house, emit a pre-alarm upon detection (optical/acoustic signal,
sounders excluded). If the intruder keeps going in and is detected by a detector connected to a
programmed zone as per the above item, the general alarm will be activated.
Warning: the detectors operating outside the house may generate false alarms due to unavoidable natural
phenomena that interact with the devices. The suitable choice of the devices, their proper installation and
programming of 2 detectors operating in AND mode on the same alarm channel allow to reduce false alarms
significantly. However, it is recommended not to connect outdoor detectors on the zones programmed as per item
1.
Note: The default operating mode is set as traditional , to set it as pre-alarm select Y and item EXTERNAL
ALARM in the related zone menu ( ALARM ZONE A, B and C ) located in programming menu DEVICES.
Activation, disactivation and partial activation
AF921
AF940R
AF978R
Full activation
Insert the user code
followed by ESC and
confirm
Press the red button
Insert the code and press
the red button
Partial activation
Insert the user code
followed by ESC, select the
zones to be included by
pressing 1,2,3 check the
display and confirm the
chosen configuration with
Press the red-black button
Note: Only zones A and B are
included
Insert the user code, select
the zones to be excluded
by pressing A, B, C and
confirm by pressing the red
button
Disactivation
Insert the user code and
press CANC
Press the green button
Insert the user code and
press the green button
The system is active following up the exit time set upon performing installation ( default 60s ). Visual and sound
confirmation is given by the buzzer seated on the control panel and can be repeated by some sounders, if any.
This function is useful to check the operations carried out with remote controls from outside. Any alarm in progress
is silenced by switch-off
Note: After a switch-on and a switch-off, function or failure signals may occur, check what happened by referring to
the event history file.