55
PROGRAMMING OF THE SYSTEM PERIPHERAL DEVICES ( EXTRAS MENU )
Wire inputs
The AF921 control panel is provided with 6 wire inputs, 2 for each zone ( A,B,C ). For each zone a delay from 0 to
99 seconds and a identification label can be set in the EXTRAS
WIRE INPUTS menu.
NOTE: These inputs are of NC type to Gnd.
AF978R Keypad for activation, disactivation and partial activation of the system
Keypad AF978R, shown in the picture, has the following technical characteristics:
Power supply: Lithium battery 3,6V-2,2 Ah. SB AA 11 (cod. AVE AF916);
Current consumption: 5mA in stand-by
40mA during transmission;
Life: over 8 years with 4 operations a day;
1 to 4-character user code;
R.F characteristics.: HF transmission, quartzed at 433,92 MHZ,
Max. power 10mW;
Signal coding: 36-bit random code, pre-set;
Working range: over 80m in open space. 30 m approx. in residential rooms;
Enclosure protected against opening and removal
Dimensions: AVE enclosure compatible with the System 45 (125x102,5x30).
Control panel AF921 allows to store up to 32 codes from the AF978R keypad.
For programming, proceed as follows:
Panic and tamper alarm:
Select menu EXTRAS followed by ;
Select menu 24H PANIC followed by ;
The first available position P01 SENSOR will be displayed, confirm with ;
INSERT BATTERY will be displayed, now insert the battery into the keypad ;
The control panel will emit a beep for confirmation. It will emit three beeps if the procedure has not been
successful.
User code programming:
Select menu EXTRAS followed by
;
Select menu KEYBOARD CODES followed by ;
The first available position CODE 01 will be displayed, confirm with ;
Now, the keypad functions can be limited by pressing keys 1, 2, 3, 4, 5 and 6 ( the enabled or disabled function
will be displayed );
Insert he battery of the keypad and conform the desired configuration by pressing ;
STORE CODE will be displayed, insert the desired code and press the RED and GREEN keys of the keypad to
be programmed at the same time. The control panel will confirm programming by emitting a Beep ;
LABEL COD 01 will be displayed, insert the name of the user of the code and confirm with ;
After programming the code, press ESC;
Note: each keypad can control up to four different codes max.
Control panel AF921 allows to delete the codes coming from the AF978R keypad individually. To delete the codes,
proceed as follows:
Select menu EXTRAS followed by
;
Select menu KEYBOARD CODES followed by ;
The first available position 01 CODE will be displayed, confirm with ;
At this point, press key CANC;
DELETE? will be displayed, confirm with ;
The control panel will emit a beep for confirmation. It will emit three beeps if the procedure has not been
successful.