Vocal message programming
6 vocal messages can be recorded, listened or changed and can be combined to a control panel event:
General alarm due to intrusion
zones A B C
Control panel and/or peripheral device tampering
Panic alarm with sounder enabling
Silent alarm for robbery/assault
Technical alarm (smoke, water, gas, etc..)
Low battery warning (control panel and/or peripheral devices)
Note: message 7 is used as the answer of the telephone dialler to any call.
Programme the vocal messages as follows:
Select MESSAGES from the menu followed by ;
Select VOCAL MESSAGES followed by ;
Select VOCAL MESSAGE 1 followed by ;
Select VOCAL RECORDING 1 and keep key
pressed during all the message
At the end of recording release key , VOCAL LISTENING 1 is displayed and the vocal message will be
reproduced.
Press ESC to confirm, CANC to delete and to store it again,
to listen to it again;
If confirmed with ESC, VOC. EVENT1 will be displayed.
Now, select the combination of the message to the related event by using keys , ;
If you want to customise the events, refer to section Advanced programming of messages.
Confirm by pressing .
Proceed in the previous way for next messages by selecting the respective messages. The overall time of the vocal
messages is 120 seconds.
Note: The vocal message is automatically connected to the related wire input.