Installing and wiring telephones and trunks
94 Installing and Connecting the MDF and Telephones
The 4-type protector is the preferred device. For installations not using primary protection,
4-type protectors should always be used. When the 3-type protector is already installed, a
separate sneak current protector is required.
The multi-pair protector units and the off-premises cabling must be locally engineered.
Connected multi-pair protector units (female 25-pair connector) are recommended.
Table 15: Analog line circuit protectors
shows the recommended protectors.
For catalogs and ordering information, go to the Avaya Cable Management Systems for Service
Providers Web site (
http://connectivity.avaya.com/exchangemax/
) and click
Products &
Solutions
.
Telephone restrictions for exposed environments
Analog telephones connected to TN746B Analog Line circuit packs cannot be installed in an
exposed environment.
Digital Out-of-Building Telephone Protection
Digital out-of-building telephones require protection at both building entrances. The 4C3S-75
Enhanced Protector and the ITW Linx Enhanced Protector can be used to protect digital
telephones and digital line circuit packs. These units provide primary and sneak current
protection. The 4C3S-75 is equipped with a heat coil for sneak current protection, and the ITW
Linx is equipped with replaceable fuses for sneak current protection.
Note:
Note:
The TN2181 16-port, 2-wire digital line circuit pack may not be approved for
some out-of-building uses. Contact your Avaya representative for more
information.
Table 15: Analog line circuit protectors
Primary
*
*. The 3-type protectors should be used only if they are already part
of the existing protection system. A sneak current protector is
always required when a 3-type primary protector is used.
Primary
(with heat coil)
Sneak current
protectors
*
3B1A (carbon)
4B1C (carbon)
220029 Fuse
3B1E-W
(wide gap gas tube)
4B1E-W
(wide gap gas tube)
SCP-1
3C1S
(solid state)
4C1S
(solid state)
Содержание 03-300686
Страница 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...
Страница 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...
Страница 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...
Страница 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...
Страница 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...
Страница 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...
Страница 108: ...Installing and wiring telephones and trunks 108 Installing and Connecting the MDF and Telephones ...
Страница 134: ...Installing and wiring telephone power supplies 134 Installing and Connecting the MDF and Telephones ...
Страница 156: ...156 Installing and Connecting the MDF and Telephones Index ...