To connect telephones and other end devices to the 1152A1 PDU:
1. Connect an Ethernet cable to the telephone using an external splitter or directly (if the
device is Power over LAN Enabled).
2. Connect the opposite end of the same cable to the RJ45 wall outlet.
3. On the front panel of the 1152A1 PDU, monitor the response of the corresponding port LED.
If it lights up GREEN, the unit has identified your telephone as a Power over LAN
1152B Mid-Span Power Distribution Units
The Avaya 1152B Mid-Span Power Distribution Units are Ethernet power supplies that provide
power to up to 48 46xx-series or 96xx IP telephones or wireless LAN (WLAN) access points.
The 1152B PDUs are designed to deliver power in addition to data communication over an
Ethernet network. The 1152B PDUs eliminate the need to connect each Ethernet Data Terminal,
such as an IP Telephone set, to an AC power outlet in addition to the data port. The system also
removes the need for power cables, local AC wall adapters and the use of a dedicated UPS for
each IP telephone. Some models support SNMP remote management via a separate physical
RJ45 input port.
These units are used with a standard 10/100BaseTx Ethernet network infrastructure using
standard TIA/EIA-568 Category 5, 5e, or 6 100-Ohm Unshielded Twisted Pair (UTP) cable. The
1152B meets the current requirements of the IEEE802.3af-2003 standard for resistive detection.
The units are as follows:
Table 21: 1152B Midspan Power Distribution Units
Avaya Model
Number
Number of
Ports
SNMP
Summary
1152B48S
48
Yes
48-port, AC Input, 48Vdc Output with SNMP
1152B24S
24
Yes
24-port, AC Input, 48Vdc Output with SNMP
1152B06
6
No
6-port, AC Input, 48Vdc Output
1152B06S
6
No
6-port, AC Input, 48Vdc Output with SNMP
Содержание 03-300686
Страница 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...
Страница 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...
Страница 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...
Страница 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...
Страница 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...
Страница 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...
Страница 108: ...Installing and wiring telephones and trunks 108 Installing and Connecting the MDF and Telephones ...
Страница 134: ...Installing and wiring telephone power supplies 134 Installing and Connecting the MDF and Telephones ...
Страница 156: ...156 Installing and Connecting the MDF and Telephones Index ...